| Programmable Thermostat | Bid must reference Programmable Thermostat |
Heating System Replacement¹* (Programmable Thermostat required): - Natural Gas or Propane Furnace: AFUE >= 95
- Oil Furnace: AFUE >= 85
- Natural Gas, Propane or Oil Hot Water Boiler:
AFUE >= 90 (ensure distribution system is compatible with a condensing boiler)
| Any one of the following: - Bid must reference AFUE rating of the furnace or water boiler to be installed.
- Copy of the product specifications indicating the AFUE rating.
- Print out of Excel or PDF list from energystar.gov indicating the to-be-installed Make and Model and its AFUE rating.
|
Air Source Heat Pump (Programmable Thermostat required) - Split ducted (central) system
- SEER2 ≥ 15.2 / SEER ≥ 16.0
- EER2 ≥ 10.0 / EER ≥ 10.0
- HSPF2 ≥ 8.1 / HSPF ≥ 9.5
- Non-ducted (mini-split) system
- SEER2 ≥ 16.0 / SEER ≥ 16.0
- EER2 ≥ 9.0 / EER ≥ 9.0
- HSPF2 ≥ 9.5 / HSPF ≥ 10.6
- Packaged systems
- SEER2 ≥ 15.2 / SEER ≥ 16.0
- EER2 ≥ 10.0 / EER ≥ 10.5
- HSPF2 ≥ 8.1 / HSPF ≥ 9.6
| Any one of the following: - Bid must reference SEER2/SEER, EER2/EER, HSPF2/HSPF rating of the air source heat pump.
- Copy of the product specifications indicating the SEER2/SEER, EER2/EER, HSPF2/HSPF rating.
- Print out of Excel or PDF list from energystar.gov indicating the to-be-installed Make and Model and its SEER2/SEER, EER2/EER, HSPF2/HSPF rating.
|
A/C Replacement* (Programmable Thermostat installation required): - Package Systems: SEER >= 14, EER >= 12 (for equipment manufactured before 1/1/2023); SEER2 >=13.4 (for equipment manufactured starting 1/1/2023)
- Split Systems: SEER >= 15, EER >= 13 (for equipment manufactured before 1/1/2023); SEER2 >=14.3 (for equipment manufactured starting 1/1/2023)
- Mini-split systems: SEER >= 15, EER >= 13 (for equipment manufactured before 1/1/2023); SEER2 >= 14.3 (for equipment manufactured starting 1/1/2023)
| Any one of the following: - Bid must reference SEER/SEER2 or EER rating of the A/C to be installed.
- Copy of the product specifications indicating the SEER/SEER2 or EER rating.
- Printout of the Excel or PDF list from energystar.gov indicating the to-be-installed Make and Model and its SEER/SEER2 or EER rating.
|
Water Heater Replacement: - Gas storage units >= 0.67 Energy Factor (EF)
- Gas tankless units >= 0.82 EF with 2.5 gpm @ 77°F rise
- Electric storage units = 0.95 EF
- Electric heat pump storage unit >=2.0 EF
| Any one of the following: - Bid must reference EF rating of the water heater to be installed.
- Copy of the product specifications indicating the EF rating.
- Print out of Excel or PDF list from energystar.gov indicating the to-be-installed Make and Model and its EF rating.
|
Light Fixtures: - Must be ENERGY STAR (ENERGY STAR CFL fixtures replace less efficient incandescent fixtures, are hardwired and use pin-based lamps).
| - Bid must reference ENERGY STAR light fixtures.
|
Insulation: - Walls: Wall cavities must be filled with insulation (if the cavity is to be filled with blown-in insulation, the cavity must be dense packed to 3.5 lbs/ft3).
- Attic: Final R-Value >= R44
- Attic Air Sealing is a prerequisite for insulation; pre- & post-blower door testing is recommended to measure effectiveness of air sealing.
| All of the following: - Bid must reference insulation requirements that wall cavities be filled with insulation and/or attic insulation have an R-value of 44 or greater, as applicable.
- Bid should also reference that attic air sealing be undertaken to the greatest extent feasible.
- If wall cavities are filled with blown-in insulation, bid must reference the cavity will be dense packed to 3.5 lbs./ 3ft.
|
Windows: - Must be ENERGY STAR qualified under federal guidelines (patio doors are eligible).
| - Bid must reference ENERGY STAR windows.
|
| Heat Recovery Ventilation System or Energy Recovery Ventilation System | - Bid must reference the system’s maximum rated sensible recovery efficiency (SRE) is at 0°C of 65% or more.
|
| Solar Panels | - Only eligible under the secured Incentive Rate Energy Conservation loan.
|